Pressure transducers and pressure transmitters engineered and manufactured by Stellar Technology, Inc. are used in all industrial sectorsaerospace, oil and gas, automotive, off-road, automation and control, medical, marine, geophysical, power generation, alternative energy, military and defense, and many more. STI provides one of the most comprehensive selections of standard pressure transducers in the test and measurement industry. STI also specializes in custom designed pressure transducers and pressure transmitters and application specific pressure transducers. Customers rely on STI’s pressure transducer design experience, direct technical support, availability of on-sight technical assistance, and responsive service.
|
Configuration
|
Model
Number
|
Description
|
Ranges
(PSI)
|
Pressure
References
|
Accuracy
%FSO*
|
CTR
(°F)
|
Hermetic
|
mV/V
|
Amplified
|
Digital
|
|
Aerospace Pressure Transducers and Transmitters
|
|
|
|
Replaceable
diaphragm
pressure
transducer
|
200-
20,000
|
G
|
L = ± 0.25%.
H = ± 0.25%.
R = ± 0.10%.
|
-30/+170
|
|
3 mV/V
|
|
|
 |
|
Replaceable
diaphragm
pressure
transmitter
|
15-
20,000
|
G, A
|
L = ± 0.25%.
H = ± 0.25%.
R = ± 0.10%.
|
-30/+170
|
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
 |
|
General purpose
pressure
transducer
|
15-
40,000
|
G, A
|
L = ± 0.20%.
H = ± 0.20%.
R = ± 0.10%.
|
-65/+250
|
Yes
|
3 mV/V
|
|
|
 |
|
Space rated
pressure
transducer
|
15-
40,000
|
A
|
L = ± 0.20%.
H = ± 0.20%.
R = ± 0.10%.
|
-65/+250
|
Yes
|
3 mV/V
|
|
|
 |
|
Space rated
pressure
transmitter
|
5-
40,000
|
A
|
L = ± 0.20%.
H = ± 0.20%.
R = ± 0.10%.
|
-60/+200
|
Yes
|
|
0-5 Vdc
|
|
 |
|
General purpose
pressure
transducer
|
15-
2000
|
G, A,
V, C
|
L = ± 0.20%.
H = ± 0.20%.
R = ± 0.10%.
|
-65/+250
|
Yes
|
3 mV/V
|
|
|
 |
|
General purpose
pressure
transmitter
|
5-
2000
|
G, A,
V, C
|
L = ± 0.20%.
H = ± 0.20%.
R = ± 0.10%.
|
-65/+250
|
Yes
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
 |
|
General purpose
pressure
transducer
|
200-
40,000
|
G, A,
V, C
|
L = ± 0.20%.
H = ± 0.20%.
R = ± 0.10%.
|
-65/+250
|
Yes
|
3 mV/V
|
|
|
 |
|
General purpose
pressure
transmitter
|
50-
40,000
|
G, A,
V, C
|
L = ± 0.20%.
H = ± 0.20%.
R = ± 0.10%.
|
-65/+250
|
Yes
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
 |
|
Cleanable
pressure
cavity
pressure
transducer
|
1 -
20,000
|
G, A
|
L = ± 0.25%.
H = ± 0.25%.
R = ± 0.10%.
|
-30/+170
|
|
3 mV/V
|
|
|
|
• L = Linearity. H = Hysteresis. R = Repeatability. |
|
Differential Pressure Transducers and Transmitters
|
|
|
|
High line
pressure
transducer
|
1-500
|
D
|
0.25%
|
-10/+160
|
|
3 mV/V
|
|
|
 |
|
High line
pressure
transmitter
|
1-500
|
D
|
0.25%
|
-10/+160
|
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
 |
|
Smaller size
pressure
transducer
|
50-
40,000
|
D
|
0.25%
|
+30/+130
|
|
1.5 mV/V
|
|
|
 |
|
Smaller size
pressure
transmitter
|
50-
40,000
|
D
|
0.25% / 0.10%
|
+30/+130
|
Yes
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
|
Data Logger Pressure Transmitters
|
|
|
|
Battery operated
pressure
transmitter
|
5-
40,000
|
G, A,
V, C
|
0.10%
|
-40/+185
|
|
|
|
CANbus,
RS-232,
RS-485
|
|
Flush Diaphragm Pressure Transducers and Transmitters
|
|
|
|
Sub Miniature
pressure
transducer
|
100-
5000
|
G
|
0.50%
|
+30/+130
|
|
1-2 mV/V
|
|
|
 |
|
Sub Miniature
pressure
transmitter
|
100-
5000
|
G
|
0.50%
|
+30/+130
|
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
 |
|
Miniature
pressure
transducer
|
2000-
10,000
|
G, A
|
0.25%
|
-65/+250
|
|
3 mV/V
|
|
|
 |
|
Miniature
pressure
transmitter
|
500-
10,000
|
G
|
0.25%
|
-30/+170
|
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
 |
|
Insensitive
to torque
sensing
diaphragm
|
2000-
10,000
|
G, A
|
0.25%
|
-65/+250
|
|
3 mV/V
|
|
|
 |
|
Insensitive
to torque
sensing
diaphragm
|
50-
10,000
|
G, A
|
0.25%
|
-30/+170
|
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
 |
|
flush
diaphragm
mates with
tri-clover
clamps
|
5-
10,000
|
G
|
0.25%
|
0/+200
|
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
|
General Purpose Pressure Transducers and Transmitters
|
|
|
|
High accuracy
pressure
transducer
|
15-
40,000
|
G, A,
V, C
|
0.10%
|
-30/+170
|
Yes
|
3 mV/V
|
|
|
 |
|
High accuracy
pressure
transmitter
|
5-
40,000
|
G, A,
V, C
|
0.10%
|
-30/+170
|
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
 |
|
Standard accuracy
pressure
transducer
|
50-
40,000
|
G, A,
V, C
|
0.25%
|
+30/+130
|
|
3 mV/V
|
|
|
 |
|
Standard accuracy
pressure
transmitter
|
5-
40,000
|
G, A,
V, C
|
0.25%
|
+30/+130
|
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
 |
|
High accuracy
pressure
transmitter
|
5-
40,000
|
G, A
|
0.05%
|
-30/+170
|
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
 |
|
Improved accuracy
pressure
transducer
|
150-
40,000
|
G, A,
V, C
|
0.15%
|
-30/+170
|
|
3 mV/V
|
|
|
 |
|
Improved accuracy
pressure
transmitter
|
5-
40,000
|
G, A,
V, C
|
0.15%
|
-30/+170
|
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
| High Capacity / Fatigue Rated Pressure Transducers and Transmitters |
|
|
|
High capacity
pressure
transducer
|
20,000-
100,000
|
G, A
|
0.25%
|
-30/+170
|
|
3 mV/V
|
|
|
 |
|
High capacity
pressure
transmitter
|
20,000-
100,000
|
G, A
|
0.25%
|
-30/+170
|
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
|
Hazardous Certification Pressure Transducers and Transmitters
|
|
|
|
CSA
approved
Intrinsically Safe
pressure
transmitter
|
5-
40,000
|
G
|
0.25% / 0.10%
|
+30/+130
|
|
|
4-20 mA
|
|
 |
|
ATEX approved
flameproof
pressure
transmitter
|
500-
20,000
|
G
|
0.25% / 0.10%
|
+30/+130
|
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
 |
|
ATEX approved
Intrinsically Safe
pressure
transmitter
|
5-
40,000
|
G
|
0.25% / 0.10%
|
-30/+170
|
|
|
4-20 mA
|
|
 |
|
CSA approved
explosion proof
pressure
transmitter
|
5-
40,000
|
G
|
0.25% / 0.10%
|
+30/+130
|
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
|
Submersible Pressure Transmitters
|
|
|
|
General Purpose
pressure
transmitter
|
5-
40,000
|
G
|
0.25% / 0.10%
|
+30/+130
|
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
|
Dual Output Pressure-Temperature Transducers and Transmitters
|
|
|
|
Dual Press./Temp.
transducer
|
5-
15,000
|
G, A,
V, C
|
0.25% / 0.10%
|
-30/+170
|
Yes
|
3 mV/V
|
|
|
 |
|
Dual Press./Temp.
transmitter
|
5-
15,000
|
G, A
, V, C
|
0.25% / 0.10%
|
-30/+170
|
Yes
|
|
0-5 Vdc;
0-10 Vdc;
4-20 mA
|
CANbus,
RS-232,
RS-485
|
|
Oil & Gas Pressure Transducers and Transmitters
|
|
|
|
Hazardous
Certifications
pressure
transmitter
|
5000-
15,000
|
G
|
0.25% / 0.10%
|
-40/+185
|
|
|
4-20 mA
|
|
 |
|
API flanges
Oilfield
Press./Temp.
transducer
|
5,000-
15,000
|
G
|
1% TEB
|
+30/+300
|
|
|
4-20 mA
|
CANbus,
RS-485
|
|
|
|
Oilfield
Press./Temp.
transducer
Cryogenic Applications
|
200-
40,000
|
G
|
0.25
|
-320/
+140
|
Yes
|
|
4-20 mA
|
CANbus,
RS-232,
RS-485
|
If you don't see the STI part number you are looking for, click here.
|
|